Specifications are subject to change without notice WM5 96 DS ENG 210708 5
WM5-96
Data stamping
Type of data Alarm, min, max, digital
input status, digital output
status as remote control,
resets. All events are stored
w
ith date (dd:MM:yy) and
hour (hh:mm:ss) reference
Number of events Up to 10,000
Data management type: FIFO
Data storage type Data flash
Displaying 4 variables per page
1
page that can be laid out by
the user
Up to 36 pages
Energy meters Up to 28 pages depending on
the selected tariff mode. Dis-
playing of the consumed
energy of the previous 12
months.
Stored events 10,000 events.
Display language Selectable:
English, Italian, French,
German, Spanish
Password Numeric code of max 4
digits from 0 to 1000;
2 protection levels of
t
he programming data
1st level Password “0”: no protection
2nd level Password from 1 to 1000:
all data are protected.
S
ystem selection
System 1 1-phase (2 wires)
System 2, unbalanced 2-phase (3 wires)
System 3, balanced 3-phase (3 wires+1CT)
System 3, unbalanced 3-phase (3 wires)
3-phase (4 wires)
Transformer ratio CT up to 30 kA (6000 max)
VT (PT) up to 600 kV
(6000 max)
Filters
Filter operating range 0.1 to 100% of the input
electrical scale.
Filtering coef
ficient 1 to 255
Filter action
Display, alarms, serial outputs
(fundamental variables:
V,A,W and their derived ones).
Alarms
Working mode “OR” or “AND” or
“OR+AND” functions (see
“Alarm parameter and logic”
page).
Freely programmable on up
to 16 alarms. The alarms
can be connected to any
variables available in the
table “List of the variables
that can be connected to”
Reset By means of the key-pad or
of the configuration software,
it is possible to reset the
following data:
- all the min, max, dmd,
dmd-max values.
- total and partial counters.
- latch alarms.
- all the events.
Software functions
Wm5Soft Multi-language software
(Italian, English, French,
German, Spanish) for
variable reading,
instrument calibration and
parameters programming.
The pr
ogram
runs under Windows
/98/98SE/2000/NT/XP.
W
orking mode
Thr
ee dif
fer
ent working
modes can be selected:
- management of local
RS232 (MODBUS);
- management of local
optical port (MODBUS);
- management of a local
RS485 network (MODBUS);
Data Storing In pre-formatted XLS files
(Excel data base).
Data T
ransfer
Manual or automatic at
pr
ogrammable timings.
Wm5Soft parameter programming and variable reading software