Portable Power Quality Analyzer PQA700 MAIN FEATURES
Display
Display language
Other indications
Accuracy
Sampling frequency
Sampling time
Measuring inputs
Type of connections
Measuring method
Available measurements
Data recording
Archives function
(by means of PqaSoft)
Other functions
(by means of PqaSoft)
Oscilloscope function
Measurements
according to EN50160
Outputs (insulated)
Printer
Power supply
Approvals
Installation Category
EMC
Operating temperature
Storage temperature
Carrying case / weight
Standard accessories
Accessories on request
Type: Graph, 240 x 64 dots (back lighted) Refresh time:500ms
Selectable: English, Italian,Spanish, German, French
Battery recharging by means of a red LED
0.5% RDG + 0.15% F.S. (5 to 120% of the voltage range, resolution: 0.1V),45 to 65Hz
0.5% RDG + 0.15% F.S.(5 to 120% of the current range),minimum measurable current:1A (1mV) ,45 to 65Hz
0.05% RDG (frequency).1% RDG all the other measurements
6400Hz @ 50Hz
For instantaneous variables:20ms / continuous. For dips:10ms
Voltage measurements: 4 (non-insulated), max. 700V
LL
RMS. Max peak value: 1600Vp for 1s
Current measurements: 3 (non-insulated, the insulation is achieved by the clamp-on probes) max. 1.4VAC
equivalent to 1400A
1-phase, 3-phase balanced load, 3-phase unbalanced load,ARON type
TRMS type, crest factor 3
Instantaneous single and system variables:W,VA, var,V,A,TPF, DPF, Hz,THD (voltage, current),odd THD, even THD
Maximum demand calculation:W,VA,A (system variables), calculation period: programmable from 1 to 60
minutes.Automatic calculation of kvar necessary to compensate low PF FRESNEL diagram indication
Maximum and minimum calculations (single phase and system variables):W,VA,var,V,A, DPF, TPF, Hz,
THD (THD is considered for both current and voltage), odd THD, even THD.
Energies: + Wh, - Wh,+ varh, - varh, +VAh, -VAh (also by time period). FFT analysis (harmonic distortion):
histogram indication up to the 50th harmonic, numerical and percentage indication of harmonic contents, of
both voltage and current.THD (total, odd, even) and single harmonic measurement.
FFT voltage range: 2 to 100% F.S.; FFT current range: 5 to 100% F.S.THD calculation according to EN61000-4-7
Type: FIFO or stack
Start measuring delay: programmable from 00:00h to 23:59h
Data integration time interval (10ms sampling) : programmable from 1 to 999s (15 min.)
Type of recording: minimum, maximum and average value or voltage DIPS
Data references: date and time (hh:mm:ss)
Total available memory: 1Mbyte
Type: stack. Measuring period: fully programmble. Data sampling time: programmable from 10 to 999 s.
Type of recording: data sampling of up to 20 selectable variables.Data references:date and time (hh:mm:ss)
Statistic management of the stored variables
Time-based curve distribution of variables and loads
Current and voltage (current and voltage of single phase available in the same display page) with automatic trigger
Supply voltage dips, slow and fast supply voltage variations, supply interruptions
RS232: 9-pole connector, programmable baud rate up to 38400
Impact dot matrix type, paper width:54mm (numerical and graph data printing)
230VAC ±15% (115VAC ±15% on request) and internal rechargeable battery power supply (battery life: 1h)
CE
III / 600V (according to EN61010-1), double insulation
EN61000-4-2 discharge: 8kV “air”level 3, 4kV “contact”level 2; EN61000-4-3 radiated field: 10V/m level 3;
EN61000-4-4 transients: 2kV level 3; EN61000-4-5 surge: 2kV; EN50011 conducted emission, class A
0 to 55°C (R.H. < 90% non-condensing)
-10 to 60°C (R.H. < 90% non-condensing)
160 x 340 x 510mm / Instrument: 3.7Kg, the whole set: 10Kg
4 voltage measuring cables, length 3m
1 RS232 cable
1 power supply cable
1 analysis software (PqaSoft)
1 instruction manual (English, Italian, Spanish, German or French)
CA 1002: current clamp probe 100-1000AAC,jaw opening 52mm, cable length 2m
accuracy: 0.7% @ 100A, 0.5% @ 1000A
Flex3000Q: current clamp probe 3000AAC, flexible type, sensor length 400mm, measuring range: 0,5A to
3000A, cable length 2m; accuracy: 1.5% @ 150A, 0.75% @ 1600A, 0.5% @ 3000A