ous variables at 4 digits or 3
1
/
2
digits.
Range, to set the operating range of the digital filter. The value is
expressed as % of the full scale value.
Coefficient, to set the filtering coefficient of the instantaneous meas-
urements. Increasing the value, also the stability and the settling time
of the measurements are increased.
Once any of the three parameters has been selected, set the desired
value by means of the and keys and confirm it with .
To exit the "Filter" menu, press
.
Var: to select the variable to be coupled to the output.
Min O: value expressed as % of the output range (0-20mA, 0-10V, etc.)
to be generated by the minimum measured value (Min In).
Max O: value expressed as % of the output range (0-20mA, 0-10V,
etc.) to be generated in correspondence with the maximum measured
value (Max In).
Min In: minimum value of the variable input range.
Max In: maximum value of the variable input range.
To exit anyone of these menus, press
.
TO SELECT THE SERIAL OUTPUT (RS485 ONLY)
Select the variable to be set by means of the and keys and
confirm the selection with .
Set the desired value and confirm it using the key.
The configurable variables are:
Address of the instrument: 1 to 255.
Baud rate: 1200, 2400, 4800 and 9600 bauds.
Parity: no parity, even parity and odd parity.
To exit the menu, press .
TO SELECT THE DIGITAL FILTER
Select the menu parameter using the and keys and confirm
it with .
There are three available selections:
Display, to select the display of the measurements of the instantane-
Seitenansicht 13