
Hardware Functions
Input/Output
Performance
The best DPM to suit your needs!
LDI35
3 1/2-DGT µP-based indicator
and controller
48 x 96 x 83 mm
Panel mounting
3 1/2-DGT or 3DGT+ dummy 0, red LED
YES
(2-20mA, 20-200V); (2-5A, 200-
500V); (TC: J-K-S-T-L, Pt100-1000,
Ni100, 200-2000 Ω)
DC and AC
Label set
DC: ±(0.3%FS + 1DGT)
AC: ±(0.5%FS + 1DGT)
±200ppm/°C
4 times per second
Not Available
Up to 1
Not Available
Not Available
Signal/display scaling. Digital
filter, Peak and valley. Burn-out
control on temperature input
24, 48, 115, 230VAC, 9 to 32VDC,
40 to 150VDC
UR, CSA, CE
IP65 (on request)
Description
Housing (H x W x D)
Mounting
Display type
Variables on display
Measured signals
Type of signals
Engineering units
Accuracy
Temperature drift
Sampling rate
Command inputs
Outputs: Alarm
Analog
Serial
Other available characteristics
Power supply
Approvals
Protection degree
This series is available in two basic models:
• LDI35, offered as an indicator only
• LDI35, with one alarm relay output
Each model has a specific version for:
• Process applications with 2-20mA and 0.2-20V-200V input
• Higher current/voltage applications with 2-5A and
200-500VAC/DC input
The range includes an ohmmeter and a temperature controller
which can accept various types of RTDs and thermocouples.
LDI35
Specifications are subject to change without notice. 11
DPM10-19.qk 1/27/05 3:08 PM Page 11
Kommentare zu diesen Handbüchern