Seitenansicht 64
60
Output module can be 200,400,480,600 VAC.
*Correct heatsink assembly required.
For further details please consult datasheet.
Dimensions (mm) H x W x D
Features
Control Specifications
Control input range
Max. input current
Control supply
Max supply current
Output Specifications
Rated operational current
Operational voltage
General Specifications
Ramp up / Ramp down
Initial torque
Bypass contactor supply
Connections
Operating temperature
Storage temperature
Approvals/Marks
References
RSC..HD..+RSO... RSC..AA..+RSO... RZ3A RR2ITypes
Switching Reversing
Soft starting and stopping of
3-phase motors
(RSC...+RSO..). Phase angle
control of 3-phase heaters
(RSC.AA..+RSO).
Switching and reversing (RZ..,
RR..).
74 x 103 x 65
Output for external
bypass contactor
10-32 VDC
1 mA
10-32 VDC
180 mA
AC53a:
5 Arms [RSO..25]
15 Arms [RSO..50]
30 Arms [RSO..90]
40 Arms [RSO..110]
150-250Vrms [RSO22..]
220-420Vrms [RSO40..]
400-510Vrms [RSO48..]
400-625Vrms [RSO60..]
0.5-30 s / 0.5-30 s
10-75%
Vcc-8VDC@150mA max.
Screw type with clamp
-20°C to +70°C
-40°C to +100°C
CE - UL - CSA
Control module
RSC-HD0M60
Output module: 400VAC
25A: RSO4025 (4kW*)
50A: RSO4025 (11kW*)
90A: RSO4025 (15kW*)
110A: RSO4025 (22kW*)
74 x 103 x 41
3-phase switching
4-32 VDC [RZ3A..D.]
5 VDC [RZ3A..LD.]
24-265 Vrms [RZ3A..D.]
23 / 15 /15 mA
AC51:
25 / 40 / 55 / 75 Arms
AC53a:
5 / 8 / 15 / 20 Arms
I
2
t for fusing (t=10 ms)
265/450/1800/6600 A
2
s
24-440Vrms [RZ3A..40.]
42-660Vrms [RZ3A..60.]
850 Vp [RZ3A..40.]
1200 Vp [RZ3A..60.]
3-phase,zero switching,
built-in transient overvolt.
protect.,LED status indic.
Screw type with clamp
-30°C to +80°C
-40°C to +100°C
CE - UL - CSA
25 A / 50 A / 75 A
3 x 400 Vrms:
RZ3A40D..
RZ3A40LD..
RZ3A40A..
3 x 600 Vrms:
RZ3A60D..
RZ3A60LD..
RZ3A60A..
74 x 103 x 41
Reversing with
interlock
10-40 VDC [RR2I..HAP]
90-140Vrms VDC [RR2I..LAP]
180-265 Vrms [RR2I..HAP]
35 / 29 /15 mA
AC51:
10 / 25 / 40 Arms
AC53a:
1.5 / 3.5 / 6 Arms
I
2
t for fusing (t=10 ms)
72 / 265 / 450 A
2
s
120-440Vrms [RR2I..40.]
120-530Vrms [RR2I..48.]
1200 Vp [RR2I..40.]
1400 Vp [RR2I..48.
3-phase,built-in transient
overvolt. protect.,interlock
revers., LED status indic.
Screw type with clamp
-20°C to +70°C
-40°C to +100°C
CE - UL - CSA
10 A / 25 A / 40 A
2 x 400 Vrms:
RR2I4005.. (0.5kW)
RR2I4015.. (1.5kW)
RR2I4030.. (3.0kW)
2 x 480 Vrms:
RR2I4805.. (0.5kW)
RR2I4805.. (1.5kW)
RR2I4805.. (3.0kW)
74 x 103 x 65
User controlled
analogue input
0-20 mA (A-input)
4-20 mA (B-input)
10-32 VDC
180 mA
AC53a:
5 Arms [RSO..25]
15 Arms [RSO..50]
30 Arms [RSO..90]
40 Arms [RSO..110]
150-250Vrms [RSO22..]
220-420Vrms [RSO40..]
400-510Vrms [RSO48..]
400-625Vrms [RSO60..]
User controlled
User controlled
Screw type with clamp
-20°C to +70°C
-40°C to +100°C
CE - UL - CSA
Control module
RSC-AAM60
Output module: 400VAC
25A: RSO4025 (4kW*)
50A: RSO4025 (11kW*)
90A: RSO4025 (15kW*)
110A: RSO4025 (22kW*)
3-Phase Control Devices
Motor Control 3 Pole Switching
Seitenansicht 64