CARLO GAVAZZI EN61036 Bedienungsanleitung Seite 18

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 40
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 17
18
Only in the version 20(90)A.
Reset of the maximum current
values
Select rESEt m from the main
menu by means of the and
keys, confirm it with ; when the
instrument asks for the reset, you
can choose, by means of the
and keys:
- no m to avoid the reset or YES
m to confirm it
Then, press to carry out the
command.
How to prevent the pro-
gramming by key-pad
Its possible to prevent access to
programming by modifying the dip-
switch under slot B. Set dip-switch 1
in position ON to inhibit program-
ming; Set dip-switch 1 in position
OFF to enable programming again.
End of programming
Use it to exit from programming and
go back to the measuring mode.
Select End from the main menu by
means of the and keys,
confirm it with .
Measuring
mode
Instruments
revision
Slot B
on
1 2
on
FREE Access
Access DENIED
RESET
Programming
Alarm
13
8
Example 2
20
Seitenansicht 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 39 40

Kommentare zu diesen Handbüchern

Keine Kommentare